7200.7自校准全盘S及砍头 修复详细全过程
CTRL+T 查看终端1024k x 16 buffer detected
ALPINE - 1_Disk M.1401-16-03 11:51
Head Mask 0000 - Switch to full int.
Spin Ready
信显示M.14
1.打开STR点M14 F级修复 ,点0头引导
2.写入SN,
3.启动自校准
时间大约1天
查看终端记录发现 停在4E且出现传说中的err43 问题
22: Log Read Not OK
Code - 43Track 0EA6C.1.087Sns 09BRty FFFF.20.20FFRtf 1822LBA 0953038C
61: Log Read Not OK
Code - 43Track 0EA65.1.1E9Sns 1FDRty FFFF.20.20FFRtf 1822LBA 0953038C
28: Log Read Not OK
Code - 43Track 0EA6C.1.108Sns 11CRty FFFF.20.20FFRtf 1862LBA 0953038C
62: Log Read Not OK
Code - 43Track 0EA65.1.24DSns 261Rty FFFF.20.20FFRtf 1822LBA 0953038C
29: Log Read Not OK
Code - 43Track 0EA6C.1.187Sns 19BRty FFFF.20.20FFRtf 1822LBA 0953038C
63: Log Read Not OK
Log 59 - No Log on Disk
Log 56 - No Log on Disk
Log 6F - No Log on Disk
Total Cert Time = 01:58:10
ASCII logging off
Power CyclingAbEnd Test 4E
1.用指令回到50级
T>N50,,22
2.回写ATA,
3.输入F指令修改容量和型号
进MHDD扫描 认盘慢 全盘SSSSSSSSSSSS,写0无效果 erase无效果
又做了一次自校准 随时查看终端记录
发现
Head1 Zone 0 target = f
Too many R/W errors. Reverted to current value 0003
Zone 1 target = f
.
.
.
看来是1头坏了
输入N50,,22中断自校准回age=50
先回写ATA
然后用F指令修改容量和型号 (任意40G的容量值和型号)
写单头的SN (参考SN和磁头对应表)
断电重起
开始砍头操作
T>Y20
T>W
操作完毕 断电重起进victoria 按F4 选择write 先写个256MB 查看效果非常完美 再次F4 write和ATX power off
出门逛街~~~ 高手
厉害
牛x 开始放案例喽 hehe 很多这样的盘
经验 谢谢 谢谢,楼主真是个无私的人,我呆会就去试一下看看 谢谢谢谢嘻嘻嘻
页: