帮忙Barracuda IV盘无法做校准?
下面就是这块盘的信息。请高手 指点 !!!Interface task reset
1024k x 16 buffer detected
SNOWMASS - 1_Disk 3.1911-20-01 12:12
Power Cycling
ATReset
Head Mask 0007 - Switch to full int.
Spin Ready
AutoRd Err 47 at 7009.00.0000
AutoRd Err 47 at 7009.00.0000
INVALID Cert Disk Code - ROM Resident Revision Required: 3.19
Command Inactive - No VALID Cert Code Detected
T>
初始化VENODR区域.........................:成功.
SN写入...................................:成功.
(AutoRd Err 47 at 7009.00.0000
AutoRd Err 47 at 7009.00.0000
INVALID Cert Disk Code - ROM Resident Revision Required: 3.19
Command Inactive - No VALID Cert Code Detected
T>N02,,22
02,,22
T>(AutoRd Err 47 at 7009.00.0000
AutoRd Err 47 at 7009.00.0000
INVALID Cert Disk Code - ROM Resident Revision Required: 3.19
Command Inactive - No VALID Cert Code Detected
T>SNOWMASS - 1_Disk 3.1911-20-01 12:12
Built for SNOWMASS,SaratogaII,NAPA,TI1761 PreAmp,VTC5833 PreAmp,InternalSpin,GC110,OneToOne,2Disk,LowDelta,196 Servos,7200RPM,8Pole,NonModGray,90MHz,Code DRAM,Early Exit,RwFeat=00AA
T> 你这个应该不是在3000里面做的,应该是磁头的问题了,也有可能是你加载的LDR不对。 楼上高手~~~~~~~~ 4代无法加LDR,必须找个好盘,用热交换开SF。 磁头的问题应该是大点,但现在我正在练习修硬盘 呢,先不相信是磁头坏了,先用其它的方法修修吧,先试热交换开SF。谢谢大家的指点~! 楼主应该是用效率源工具做的吧。 换个板试,不行就热换,跑步过02就没戏了 SNOWMASSSNOWMASSSNOWMASS