xiaoyuzai 发表于 2008-4-29 22:28:02

F级问题

(1)
Error Reading Boot Adaptives
F>
e c r = 0 0 1
e c r = 0 1 0
F>ALPINE - 1_Disk    M.1401-16-03 11:51
Built for ALPINE,GRAND,Diamondback,TI1761 PreAmp,InternalSpin,SVC123,OneToOne,2Disk,LowDelta,220 Servos,7200RPM,8Pole,NonModGray,100MHz,Code DRAM,Early Exit
F>Pgm=00 Trk=0000E37B(0000E37B).0(0).1AA(1AA) Zn=00 Err=A2 ErCt=0000 Hlth=0000 CHlth=0000 Ready LBA=00000000

F>
Age=00 Type=00 MxCyl=0000E386 MxHd=00 MxSct=280 BSz=0800 TCode=0000
F>r

cmd08,paramsE37B 0000 0000 0001 0200 0010 FF00 0000 0000 0000 0000
    Code - 43Track 0E37B.0.000Sns 000
F>

(2)
IHead Mask 0000 - Switch to full int.
            Spin Ready
Interface task reset
1024k x 16 buffer detected
ALPINE - 1_Disk    M.1401-16-03 11:51
Head Mask 0000 - Switch to full int.
            Spin Ready
Interface task reset
1024k x 16 buffer detected
ALPINE - 1_Disk    M.1401-16-03 11:51
Head Mask 0000 - Switch to full int.
            Spin Ready
Interface task reset
1024k x 16 buffer detected
ALPINE - 1_Disk    M.1401-16-03 11:51
Head Mask 0000 - Switch to full int.
            Spin Ready
Interface task reset
1024k x 16 buffer detected
ALPINE - 1_Disk    M.1401-16-03 11:51
Head Mask 0000 - Switch to full int.
            Spin Ready
........................................

两块相同的盘st380011a,接电源直接进f,无法做备份,该怎么加载ldr做sf呢?
第一块盘a2错误?还是43错误?第2块不断重复以上信息,进安全模式停止.
请高手指点这两块盘该怎么做




以上问题已解决但新问题来了:
2008.05.04

1.Test: Packet flow loading (SDLD)

Object................... : App code
HDD profile file......... : C:\Program Files\ACE Lab\PC-3000\Bin\!Profiles\SeagateBara\ST380011A-3.06-3JV8EW9X-137\ST380011A-3.06-3JV8EW9X-137\Data\PCHSDump\PCHS 0x00E9D0_0x00_0x0000(0x0280).chs

Object................... : CERT code
HDD profile file......... : C:\Program Files\ACE Lab\PC-3000\Bin\!Profiles\SeagateBara\ST380011A-3.06-3JV8EW9X-137\ST380011A-3.06-3JV8EW9X-137\Data\PCHSDump\PCHS 0x00E9E4_0x00_0x0000(0x0280).chs

Object................... : CERT tables
HDD profile file......... : C:\Program Files\ACE Lab\PC-3000\Bin\!Profiles\SeagateBara\ST380011A-3.06-3JV8EW9X-137\ST380011A-3.06-3JV8EW9X-137\Data\PCHSDump\PCHS 0x00E9E4_0x00_0x0240(0x0040).chs

Object................... : ATA overlay
HDD profile file......... : C:\Program Files\ACE Lab\PC-3000\Bin\!Profiles\SeagateBara\ST380011A-3.06-3JV8EW9X-137\ST380011A-3.06-3JV8EW9X-137\Data\PCHSDump\PCHS 0x00E9E5_0x00_0x0000(0x0280).chs

Start App code........... : Yes
Force write.............. : Yes
Init zone allocation..... : Yes
Save App code............ : No
Save CERT code........... : No
Save CERT tables......... : No
Save ATA overlay......... : No
Save System Sector....... : No
走到这里停了,不知道该怎么做,第2天重做sf反复按n2,,22 ctrl+T无反应,停留在T>(这块sn:3jv9lkh4)


2.
加载完app几个模块成功后做不了sf显示:
F>
T>n2,,22
T>n2,,22
T>n2,,22
Command Inactive - No VALID Cert Code Detected
T>n2,,22

跟上面那块盘后期反应一样(sn:st3jv9h69q)

上面两块盘都是380011A

[ 本帖最后由 xiaoyuzai 于 2008-5-5 15:10 编辑 ]

elfa 发表于 2008-4-30 16:37:51

先加LDR,加完了就T>了

elfa 发表于 2008-4-30 16:38:33

加LDR需要找前4位一样的,才可以用

xiaoyuzai 发表于 2008-5-2 01:07:51

sf的时候进入sdld界面有5个选项
flash rom downing
app code....
cert code ....
cert table ...
ata overlay....是否都要勾选还是只勾选app certcode和certtable三项?
另外actions下面三项是否也要勾上呢?

weilanse 发表于 2008-5-3 20:03:21

鹏到一样的问题了债。。
希望可以解决!

22168060 发表于 2008-5-4 11:12:50

那效率源的怎么办?怎么加?

peixianlixia 发表于 2008-5-5 15:50:47

我也有过这样的问题,但我忘记怎么修的了, 对了好想是加了四项在从过下就好了 ,问题不是多难自己看下教程就搞定了

zhhustc 发表于 2008-5-7 16:59:32

要加正确的APP、CERT、CERT TABLE、VENDOR才可以开SF

zhhustc 发表于 2008-5-19 20:14:44

app code的是0x0180不是0x0280

zhhustc 发表于 2008-5-19 20:16:52

app code的是0x0180不是0x0280
页: [1]
查看完整版本: F级问题