EEEXEON 发表于 2016-9-10 09:58:21

低格断电再启动Starting LBA of RW Request= Length= 然后无限循环

Spin Up
TCC-0027

Trans.

Rst 0x40M

MC Internal LPC Process

Spin Up
TCC-0027

(P) SATA Reset


(P) SATA Reset

SIM Error 3005 LBA 00000000000977A6 FD FC36C093
RW Error 00000080

MCMainPOR: EXCEPTION: SIM aborted prior to MCMT read

MCMainPOR: EXCEPTION: POR Failed General

MCMainPOR: Feature Disabled...

Starting LBA of RW Request=0000000000087F84Length=000001CC
ProcessRWError -Read-   at LBA 0000000000087F84Sense Code=C4090082

Starting LBA of RW Request=0000000000087F88Length=000001C8
ProcessRWError -Read-   at LBA 0000000000087F88Sense Code=C4090082

Starting LBA of RW Request=0000000000087F8CLength=000001C4
ProcessRWError -Read-   at LBA 0000000000087F8CSense Code=C4090082

linshuy1 发表于 2016-9-10 12:21:02

等就可以认盘了,

堆栈溢出 发表于 2016-9-10 18:04:06

这种盘请耐心等待。Length=000001C8 相当于是倒计时一样,这个数值会越来越小,等他变为0的时候一般硬盘就会就绪了。这种盘通常是有一些坏道或者一些固件模块有损坏,可以重建编译器试试修复,如果重建失败的话可以用MRT数据恢复工具修复,效果很好。

寻求真理 发表于 2016-9-11 11:53:08

2T还是1T我直接换好盘补小小维修费,质保一年包换

jimmyyjh 发表于 2018-1-9 10:57:09

固件或磁头不稳定
页: [1]