兄弟们帮忙看下F级7200.7
型号ST380011A-8.01-M21-4JV3JV10故障表现为F级,终端显示如下:
Interface task reset
1024k x 16 buffer detected
ALPINE - 1_Disk M-2111-25-03 18:53
Error Reading Boot Adaptives
F>
现使用八喜刚更新的固件ST380011A-8.01-M21-255-4JV1V2NW
安全模式下写入APP,CERT CODE,CERT TABLE
写入方法如图1。
写完毕后出现下面信息并进入T级
Selected family......................... : Barracuda 7200.7
Selected model.......................... : ST380011A
Model by ID............................. : <HDD ID NOT READ>
Detection of HDD COM port baud rate..... : 9600
COM transfer baud rate set to 921000
Terminal : detecting SA bounds...
Detection of SA bounds by MUX
SA bounds identified
Test: Packet flow loading (SDLD)
Object................... : App code
HDD profile file......... : C:\Documents and Settings\pc\桌面\ST380011A-8.01-M21-255-4JV1V2NW\ST380011A-8.01-M21-255-4JV1V2NW\Data\PCHSDump\APP_PCHS 0x00EC80_0x00_0x0000(0x0180).chs
Object................... : CERT code
HDD profile file......... : C:\Documents and Settings\pc\桌面\ST380011A-8.01-M21-255-4JV1V2NW\ST380011A-8.01-M21-255-4JV1V2NW\Data\PCHSDump\CERT_PCHS 0x00EC94_0x00_0x0000(0x0244).chs
Object................... : CERT tables
HDD profile file......... : C:\Documents and Settings\pc\桌面\ST380011A-8.01-M21-255-4JV1V2NW\ST380011A-8.01-M21-255-4JV1V2NW\Data\PCHSDump\TABLE_PCHS 0x00EC94_0x00_0x0244(0x003C).chs
Start App code........... : Yes
Force write.............. : Yes
Init zone allocation..... : Yes
Save App code............ : Yes
Save CERT code........... : Yes
Save CERT tables......... : Yes
Save ATA overlay......... : No
Save System Sector....... : No
Downloading.............. : App code
SDLD : try to repeat transfer of block 2
SDLD : try to repeat transfer of block 8
SDLD : try to repeat transfer of block 11
SDLD : try to repeat transfer of block 13
SDLD : try to repeat transfer of block 13
SDLD : try to repeat transfer of block 14
SDLD : try to repeat transfer of block 14
SDLD : try to repeat transfer of block 14
Result.................................. : Ok
F>
Starting App code....................... : Ok
Downloading.............. : CERT code
Result.................................. : Ok
T>
Downloading.............. : CERT tables
Result.................................. : Ok
T>
Force write............................. : Ok
Init. zone allocation................... : Ok
Saving SA elements after Flash writing or App code loading is impossible!
然后在T级
输入N2,,22回车
Ctrl+T
执行自检
2分钟后完毕了
出现下面信息
Interface task reset
1024k x 16 buffer detected
ALPINE - 1_Disk M-2111-25-03 18:53
Error Reading Boot Adaptives
F>
T>
T>N2,,22
T>No valid SeaDex script in buffer.
Begin Test 02
ASCII logging on
Not Power Cycling
ERROR: No Serial Number
ASCII logging off
Code - 47Track 0E31F.0.006Sns 006Rty FFFF.20.20FFRtf 1800LBA 00000000
Code - 47Track 0E31F.0.006Sns 006Rty FFFF.20.20FFRtf 1800LBA 00000000
Code - 47Track 0E31F.0.006Sns 006Rty FFFF.20.20FFRtf 1800LBA 00000000
Code - 47Track 0E31F.0.006Sns 006Rty FFFF.20.20FFRtf 1800LBA 00000000
Code - 47Track 0E31F.0.006Sns 006Rty FFFF.20.20FFRtf 1800LBA 00000000
!!! Adaptives corrupt !!!
AbEnd Test 02
T>
此现象是不是SA有缺陷呀,
偶不知道该怎么下手修复了
下步该怎么个操作?
8C不忙了帮我看看
各位高手指点下 2楼里的到了最后
T>N2,,22
T>No valid SeaDex script in buffer
这里的时候
当时我设置的是安全模式
所以停转了
这次我全部在正常模式下操作
到了
T>N2,,22
T>No valid SeaDex script in buffer
这里
虽然硬盘还转
但是在这里停留好久
都没跑下去
如果E4E查看的话
会这样显示
T>E4E
No log 4E on disk
T> 首先第一步数据传输就有错,SDLS TRY这是提示,降低速度试试,我也不太会 引用第5楼telbbs于2006-12-30 17:16发表的:
谢谢数字
刚才又试了下
调低速度写APP没报错
才发觉一开始就只有0头
T>Age=60 Type=20 MxCyl=16358 MxHd=0 MxSct=44C BSz=0000 TCode=0000
.......
cert信息有问题;
页:
[1]