guilin_100 发表于 2012-6-13 19:49:31

5400.4 自校准不过

5400.4

I,,22 和 N2,,22

都出现以下现象,请教高手怎么解决

Cleaning trks
Unable to write Logical track 64 affected by clearance measurement, error 66
Unable To Clean Wedge Written Tracks (00.66)
RETRY # 1
Seek To 282(259).0
Waiting for AFC 1x to converge.
DZF 734782,M 41,N 0,F 4,BPW 3440
Screen Trk
Ov0,Od0,Iw0,RH0,WH0

Collect 4 Samp
0.133,0.053
0.074, -0.057
0.203, -0.028
0.090,0.028
0.125, 0.00021, 0.2500.001
Ov6,Od4,Iw6,RH0,WH1
WH Cntct Srch
C, 1,0.000, 0.00
S, 1,0.000, 0.00 Unable to Collect Test PES Data - 66
Failed To Determine Contact Pt., Error 00, Ovs 6, Iw 6

Cleaning trks
Unable to write Logical track 282 affected by clearance measurement, error 66
Unable To Clean Wedge Written Tracks (00.66)
RETRY # 2
Seek To 500(459).0
Waiting for AFC 1x to converge.
DZF 734782,M 41,N 0,F 4,BPW 3440
Screen Trk
Ov0,Od0,Iw0,RH0,WH0

Collect 4 Samp
0.047,0.016
0.078, -0.057
0.059, -0.113
0.063,0.016
0.063, 0.00001, 0.2500.034
Ov6,Od4,Iw6,RH0,WH1
WH Cntct Srch
C, 1,0.000, 0.00
S, 1,0.000, 0.00 Unable to Collect Test PES Data - 66
Failed To Determine Contact Pt., Error 00, Ovs 6, Iw 6

Cleaning trks
Unable to write Logical track 500 affected by clearance measurement, error 66
Unable To Clean Wedge Written Tracks (00.66)
RETRY # 3

老兵 发表于 2012-6-13 20:48:53

这明摆着是0头不好,砍了0头再开SF

kof_wex 发表于 2012-6-13 22:14:02

我也有个5400.4的,开SF,始终过不了02.

勇创 发表于 2012-6-14 01:28:33

本盘大多要K头的

delete 发表于 2012-6-15 19:17:53

磁头不行了,不要了吧

guilin_100 发表于 2012-6-15 23:31:22

确实是0磁头损坏,用ROM+APP砍0头,SF搞定了,多谢大家指点

syzdq 发表于 2012-6-18 09:40:03

改什么ROM和APP啊,直接k0多方便。

asbule 发表于 2012-9-14 17:06:16

555555没金子啦

zhan857 发表于 2013-12-25 00:08:32

来学习了哦....
页: [1]
查看完整版本: 5400.4 自校准不过